Commercial ventilation

Overview

Systemair has been supplying commercial projects with highly efficient, highly impactful HVAC solutions for almost 50 years. Enabling you to deliver comfortable indoor environments without compromising on energy, design, or functionality.

Roof

Geniox VOClean Air Handling Units
High-performing, energy-saving ecology units designed specifically for commercial kitchen applications.

Excellent at capturing and removing airborne pollutants with airflows ranging from 2,500 m³/h to 40,000 m³/h

Ideal for commercial kitchens and catering establishments of all ranges.

Good thermal and sound insulation with 60 mm panels.

Staircase

ORV Dampers

  • Overpressure release valve - passive element with quick response

  • Automatic operation 

  • Temperature range -20 ÷ 80°C 

  • Zinc-magnesium coated frame 

  • Pre-set pressure difference

MUB Fan

  • Efficient fans for supply or exhaust ventilation systems

  • Flexible airflow direction due to removable panels

  • Indoor and outdoor installation

  • Modular system of accessories

  • ZM310 casing panels with corrosion class C5

Gym

CAP Diffusers

  • CAP diffusers are supply and return air diffusers that use multiple nozzles to quickly and evenly distribute the airflow in any room.

  • Excellent for comfort ventilation systems in classrooms, offices, medical centres, shops, and more.

Topvex TR

  • Top connected air handling units with rotary heat exchangers and airflow range: 420 up to 6.900 m³/h.

  • Rotary heat exchangers

  • High performance, heat recovery

  • Fits through 900 mm openings

Lobby

Ruwen Revolving Doors Air Curtains

  • Discreet and energy-efficient air curtain for revolving doors

  • Neat and Discreet

  • Intelligent Control

  • Optimized Performance

Nova Grill

  • Adjustable air diffusion grille, for supply or extract air. Ideal for commercial and industrial premises.

  • Adjustable

  • Large free area

  • Low pressure loss & sound

  • Lightweight

  • Commercial & industrial use

  • Anodized aluminum

Serena W

  • High Wall Fan Coil Units

  • Cooling & Heating capacity from 1.23 to 3.76 kW, Airflow from 205 to 790 m3/h

  • AC and EC fan motors 

  • Silent units

  • Easy installation and maintenace

  • Precise and complete selection on AC SELECT

Basement

Geniox HP DFN

  • Air handling unit with integrated reversible heat pump using natural refrigerant R290. Airflow range: 0.26 – 2.20 m³/s (935 – 7 900 m³/h).

  • Compliant with F-gas regulation and PFAS-free

  • Natural refrigerant R290 (ultra-low GWP 0.02)

  • Energy efficient operation, total heat recovery up to 90%

  • High COP (up to 16) and EER (up to 9) values

  • Fits through 900 mm door openings

Roof

Polarix NEO Heat Pump

  • Leading the way in efficient sustainability.

  • Capacity: 35-75 kW

  • R290 natural refrigerant (0,02 GWP)

  • Wide operating limits

  • Precise and complete selection on AC SELECT

Geniox air Handling Unit

  • Airflows from 750 to 110,000 m³/h (0.21 - 30.6 m³/s)

  • Easy to configure, control and operate

  • Minimum energy use and durable design

  • #HygienicByDesign options available for the entire range

  • Systemair Access Controls system with wireless communication

  • Configurations: inline, stacked and side-by-side units

  • Heat exchanger options: rotary, counterflow, crossflow and run-around coil

  • Integrated heatpump: two variants

DVV Roof Smoke Fans

  • A reliable smoke and heat extract roof fan with continuous ventilation.

  • 400°C (F400) and 600°C (F600) / 120min

  • Daily ventilation up to 120°C

  • Smoke and gas extraction

  • Robust steel and aluminium casing

  • Vertical discharge

Hotel room

Hella Diffusers

  • Linear slot diffuser for efficient air supply in comfort ventilation systems

  • Easy installation 

  • Modern slim design 

  • Slider adjustment 

  • Precise adjustment

Serena M

  • Ducted Fan Coil Units (medium static pressure)

  • Cooling & Heating capacity from 1,5 to 8.6 kW

  • Airflow from 205 to 1 425 m3/h

  • Available Static pressure up to 80 Pa

  • Low energy consumption EC fan

  • Precise and complete selection on AC SELECT

TSO Diffuser

  • Square supply and extract diffuser suitable for ceiling installation in various settings

  • Ceiling assembly 

  • Perforated front plate 

  • High induction 

  • Adjustable distribution

Office

Optima R LV

  • Incredibly precise, low-velocity VAV controller for demand-oriented ventilation

  • Extends the range of VAV controllers for areas with airflow velocity as low as 0.2 m/s.

  • Pressure operation range from 2 Pa - 600 Pa.

  • Electric controllers can operate for air supply or air extract.

Serena C

  • Cooling & Heating capacity from 0.6 to 7.4 kW

  • Airflow from 105 to 1 500 m3/h

  • AC or EC fans

  • Vertical or horizontal installation, With or without cabinet

  • Highly customizable

  • Precise and complete selection on AC SELECT

FDR-3G Fire Damper

  • Versatile fire damper that covers most of your designer needs

  • Great variety of installations rated up to EI120S

  • Tightness class 3C as standard

  • Changeable mechanism

  • Modulated actuator suitable for system balancing

Shop

Serena K

  • Cassette Fan Coil Units

  • Cooling & Heating capacity from 1,3 to 15.0 kW

  • Airflow from 310 to 2 480 m3/h

  • AC or EC fans

  • Aesthetic and unique design diffusers

  • Precise and complete selection on AC SELECT

  • Multiple choices of color available on request

VVKR-F Swirl Diffusers

  • Square swirl diffuser suitable for T-bar suspended ceiling installation

  • Simple design 

  • Easy installation 

  • Variable air discharge 

  • Excellent induction rate

FDR-3G Fire Damper

  • Versatile fire damper that covers most of your designer needs

  • Great variety of installations rated up to EI120S

  • Tightness class 3C as standard

  • Changeable mechanism

  • Modulated actuator suitable for system balancing

Optima R LV

  • Incredibly precise, low-velocity VAV controller for demand-oriented ventilation

  • Extends the range of VAV controllers for areas with airflow velocity as low as 0.2 m/s.

  • Pressure operation range from 2 Pa - 600 Pa.

  • Electric controllers can operate for air supply or air extract.

Basement

AJ Jet Fan

  • Axial jet fan for various temperature ranges and car park applications

  • F300 and F400 versions

  • Performance tested