BEF-Q

Axial Fan with Extra Low Noise Operation

  • Extra quiet operation

  • Protection class IP45

  • Closed ball bearings

  • Integrated back draft damper

  • Vertical and Horizontal installation

  • Version with Timer and Humidity sensor

  • Version with Timer and Motion sensor

Durable

The casing and impeller are made of high-quality and durable UV-resistant plastic. High ingress protection rating makes the fan the ideal solution for ventilation of a bathroom or other domestic premises. The electronic components are protected with tight covers.

Low noise

A precision-engineered aerodynamic impeller design guarantees a powerful yet whisper-quiet ventilation performance.

High protection class

A high IP45 protection class provides secure and stable operation, even when installed in wet areas or locations with significant moisture levels.

Control options

In addition to the Basic version, the BEF-Q range can also be supplied with integrated control options, combining a Timer with either a Humidity or a Motion sensor:
Basic – without any additional functions.
TH Version – equipped with a delay Timer and a Humidity Sensor for automatic moisture-based operation.
TP Versionequipped with a delay Timer and a Motion Sensor (detection range up to 4 m, viewing angle up to 100°).

Construction

Casing made of high-quality ABS provides long lasting shock-proof and robust construction with IP45 protection degree.

The unit is finished in white RAL 9010 and are UV resistant. Fan has integral back-draught shutter to prevent air flowing back into the room when the fan is OFF.

Motor and Impeller

The advanced impeller design delivers high efficiency while maintaining low noise levels. The single-phase AC motor is housed in a high-performance, anti-vibration enclosure to ensure quiet and smooth operation. Maintenance-free ball bearings provide long service life. BEF fan motors are designed for 50 Hz operation and come equipped with integrated thermal protection as standard.

Installation and Control

Fans are designed for installation on walls or ceilings.

Basic version fan can be manually operated via a separate ON/OFF switch or the light switch.

TH version fan starts when the switch is turned ON or when the indoor humidity level exceeds the adjustable set point (60%–90%). After the switch is turned OFF, or once the humidity level drops below the set value, the fan continues to run for the duration set on the timer, adjustable from 2 to 30 minutes.

TP version fan starts when the motion sensor is activated. After the motion sensor is turned OFF, the fan continues to run for the duration set on the timer, adjustable from 2 to 30 minutes.