undefined
undefined

Sense RT

A compact heat recovery unit for outdoor roof installation

  • Compact casing with 50 mm insulated panels

  • Outdoor-ready (roof cover & inlet/outlet hoods)

  • Designed for outdoor use, -20 °C to +60 °C, IP43

  • Efficient EC fans with pressure monitoring

  • Smart air filtration with sensor monitoring

  • Integrated temperature sensors with anti-freeze protection

Compact and Weatherproof Design

Robust monobloc casing with 50 mm insulation and magnelis panels. Ideal for indoor and outdoor use.

Efficient EC Fans with Sensor Control

Low-noise EC fans with pressure sensors ensure smart, energy-saving ventilation.

Certified Heat Recovery with Bypass

EUROVENT-certified counterflow exchanger with integrated bypass for optimal energy efficiency.

High-Performance Air Filtration

2-stage supply filters (coarse 60% + ePM1 60% Extract filter - ePM10 50%) with clogging detection ensure clean air.

Fresh Air, Straight from the Roof

Fresh air made for schools

The Sense RT is a compact roof-mounted air handling unit designed to supply fresh air directly into classrooms through the roof, ensuring efficient ventilation without compromising indoor space.

With silent operation, smart integrated controls, and low-maintenance design, the Sense RT is ideal for schools looking to upgrade air quality easily and effectively.

Control System

Smart ventilation. Fully under control.

The integrated control system that turns your ventilation unit into a smart, responsive, and energy-efficient climate solution. With its intuitive 3,5" touchscreen, advanced operating modes, it gives you full control over airflow, temperature, and system behavior.

Casing

The unit is compact monobloc with frameless self-supporting construction made of sandwich panels with 50 mm thickness. The sandwich panels are made of magnelis and mineral wool with thermal conductivity 0.042 W.m-1.K-1 (EN 12667). The unit is fitted with rain protection features, including a roof cover powder-coated and inlet/outlet hoods - mangelis, all constructed from powder-coated metal sheets.

Operating conditions


The unit is designed to be operated at an indoor and outdoor environment and at an ambient temperature in the range from - 20 °C up to + 60 °C, for transporting standard atmospheric air that is free of dust, grease, chemical emissions and other impurities. The unit, when installed in the ducting system has an IP rating of IP43. 

Fans

The supply and extract of the unit is equipped with statically and dynamically balanced centrifugal fans with EC motors and backward curved impellers. The fan motors are fitted with maintenance free ball-bearings and thermal protection. Inlets of the fans and the outlet into the supply ducting are fitted with pressure transmitters.

Counterflow heat recovery core

The unit is fitted with removable an aluminium or an enthalpy counterflow desk-plate heat recovery core. The recovery core is EUROVENT certified. The recovery core has an integrated by-pass damper with a servo drive with a fluent control. 
The unit is fitted with two condensate trays with a connection for condensate drainage – at exhaust air (EHA) and at supply air (SUP).

Air filters

The unit is fitted with air filters that are monitored by pressure transmitters for level of clogging. Supply pre-filter class is Coarse 65%, supply filter class is ePM 1 60% and extract filter class is ePM 10 50%. Access to filters exchange is through the side service doors.

Heaters

Integrated electric pre-heater is fitted with switching elements (SSR) and safety elements protecting against overheating (operational and safety thermostats with manual reset and temperature sensors). 

Temperature sensors

The unit is fitted with temperature sensors – inlet (ODA), supply (SUP), extract (ETA). The unit has an integrated a multi-stage anti-freeze protection for the heat recovery core.