C2015-04.06.D9

Release notes 2015.04.06.D9

General

-

 

Danvent DV

Heat pump (DVU-HP)

A new cooling/heating unit is added to DV and TIME. It is available in the following unit sizes:

  • DV          20, 25, 30, 40, 50, 60, 80
  • TIME      20, 25, 30, 40

DK-01

Placement of DVB sections

DVB sections can now be placed at each side of the upper airflow, in a double height unit.

It can be used if upward connections are needed.

 

Control system accessories for DV unites without control system

For DV units without control system, it is now possible to select accessories that previous only was selectable with control system.

  • Pressure transmitter
  • Filter guard
  • Damper motors

 

Pictures for select unit type

When selecting supply units, mixing units or empty units the text in the selection box is replaced with pictograms.

 

Definition of primary working mode

If there is a mixing section, it is now possible to specify witch dimensioning working point to use.

  • 100 % airflow in all sections
  • Mixing ratio based on winter input
  • Mixing ratio based on summer input

If a mixing ratio of 50 % in winter is selected as dimensioning working point, functions in supply air flow before, and extract air after the mixing section will be calculated with 50 % airflow.

DK-02


Fan Description in Printout

A fan description is added to the printout in the fan section. The fan description is identical to the description printed on the label that is on the fan.

DK-03


Drip tray material change to AlZn185

When selecting Drip tray the word “Standard“ is replaced with AlZn185 (AluZink).

Now the choices are AlZn185 or Stainless steel.

 

Selecting language for User Manuals

The use can now select, in which language the User Manuals shall be delivered in.

DK-04


TIME

TIME with fan outlet on top

In TIME units with rotary heat exchangers, it is now possible to select fan outlet on top for the extract fan.

DK-05

DK-06

Corrigo 3.4

The control system in TIME is updated with a new version of the controller.

This eliminates the need of having a control box cabinet in the extract air fan.

 

DVCompact

Corrigo 3.4. has been implemented for DVCompact range. It has made a change in the concept for a control system. Now control is based on one Corrigo E28 controller.

PM motors have become available for sizes DVCompact 10 and 15 for units with heat recovery. 

DVCompact LIVING

LIVING is a new series of air handling units for heat recovery in multi-occupancy buildings with extract air ventilation. They are presented in two versions: LIVING HP with integrated heat pump and LIVING HR for connection to external heat pump. 

DVCompact Living_HP_(rendering)

DVCompact_Living_HR_(rendering)

 

Topvex

New Topvex TR & SR

Topvex TR and SR have been updated according to the “Facelift” product update, new unit item numbers, fans, exchangers, VAV fan control as accessory, etc.

SystemairCAD_Topvex_TR SystemairCAD_Topvex_SR


New false ceiling unit Topvex FC

The new false ceiling range, Topvex FC, added. Very energy efficient flat units with EC fans and counter flow heat exchangers. Available in 3 sizes.

SystemairCAD_Topvex_FC

×
×
×
×
×
×
×